No products
ASTM A807/A807M-02e1
Standard Practice for Installing Corrugated Steel Structural Plate Pipe for Sewers and Other Applicationsstandard by ASTM International, 04/10/2002
1.1 This practice covers procedures, soils, and soil placement for the proper installation of corrugated steel structural plate pipe, pipe-arches, arches, and underpasses produced to Specification A 761/A 761M, in either trench or embankment installations. A typical trench installation and a typical embankment (projection) installation are shown in , respectively. Structural plate structures as described herein are those structures factory fabricated in plate form and bolted together on site to provide the required shape, size, and length of structure. This practice applies to structures designed in accordance with Practice A 796/A 796M.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3 The values stated in either inch-pound units or SI units shall be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining values in any way. SI units are shown in brackets in the text for clarity, but they are the applicable values when the installation is to be performed using SI units.
No products